H391 Series
Print This Page  Print PDF Catalog Page(s)

 

 

 

English Metric

H391 Series Modular Line Post Insulators [3.0" Rod]
Catalog Number Line Voltage MDCL (lbs) Section Length (in) Dry Arc (in) Leakage (in) Dry Electrical Flashover (kV) 60 Hz Wet Electrical Flashover (kV) 60 Hz CIFO+ (kV) Neg (kV) CIFO Weight Ea (lbs)
H391032FX01 46 6053 32.0 19.4 36.7 198 178 336 422 71.2
H391032FX02 46 6053 32.0 19.4 51.2 198 178 336 422 74.1
H391036FX01 46 & 69 5100 36.0 23.6 40.8 236 215 402 494 73.4
H391036FX02 46 & 69 5100 36.0 23.6 60.2 236 215 402 494 77.3
H391040FX01 69 4461 40.0 27.8 59.5 274 252 468 563 78.5
H391040FX02 69 4461 40.0 27.8 78.9 274 252 468 563 82.4
H391045FX01 69 & 115 3792 45.0 33.0 69.6 322 297 551 643 82.3
H391045FX02 69 & 115 3792 45.0 33.0 93.8 322 297 551 643 87.1
H391051FX01 115 3263 51.0 39.3 104.9 378 350 651 734 91.4
H391051FX02 115 3263 51.0 36.3 119.4 378 350 651 734 94.3
H391055FX01 115 & 138 2947 55.0 43.5 104.3 415 384 717 789 92.6
H391055FX02 115 & 138 2947 55.0 43.5 123.6 415 384 717 789 96.5
H391060FX01 138 2674 60.0 48.7 114.3 461 427 800 854 96.3
H391060FX02 138 2674 60.0 48.7 138.5 461 427 800 854 101.2
H391066FX01 138 & 161 2384 66.0 55.0 120.6 517 477 899 944 99.6
H391066FX02 138 & 161 2384 66.0 55.0 154.5 517 477 899 944 106.4
H391071FX01 161 2179 71.0 60.2 130.7 562 518 981 1022 103.3
H391071FX02 161 2179 71.0 60.2 169.4 562 518 981 1022 111.1
H391076FX01 161 2030 76.0 65.4 140.7 607 558 1062 1099 107.0
H391076FX02 161 2030 76.0 65.4 184.3 607 558 1062 1099 115.8
Notes:

1) STL ( Specified Tensile Load) - 20,000 Lbs. [89.0 kN]
2) H391 Series supplied with standard G3-0 Bendable Gain Base
3) For Flat Base F3-0, change the "9" in H391... to "1" = H311 (See base section for details)
4) For Trunnion end fitting, change the "1" in H391 ... to "2" = H392 (Trunnion limits MDCL to 2500 lbs)

5) FX - Electrical Data is without Corona Ring
6) FA - Electrical Data is with a 6" Corona Ring on the line end fitting
7) FB - Electrical Data is with a 12" Corona Ring on the line end fitting
8) FE - Electrical Data is with two 12" Corona Rings on the line and tower end fittings
9) For other ratings or custom insulator designs, contact your local MPS Sales Representative

 

H391 Series Modular Line Post Insulators [3.0" Rod] Continued...
Catalog Number Line Voltage (kV) MDCL (lbs) Section Length (in) Dry Arc (in) Leakage (in) Dry Electrical Flashover (kV) 60 Hz Wet Electrical Flashover (kV) 60 Hz CIFO+ (kV) CIFO- (kV) Weight (lbs) Net Weight (kg)
H391081FA01 230 1882 81.0 69.5 184.7 642 588 1125 1159 122.5 55.6
H391081FA02 230 1882 81.0 69.5 208.9 642 588 1125 1159 127.4 57.8
H391086FA01 230 1744 86.0 74.7 289.9 687 627 1206 1235 125.3 56.8
H391086FA02 230 1744 86.0 74.7 219.0 687 627 1206 1235 131.1 59.5
H391092FA01 230 1634 92.0 91.0 234.9 740 672 1301 1326 127.6 57.9
H391092FA02 230 1634 92.0 91.0 234.9 740 672 1301 1326 136.3 61.8
H391097FA01 230 1542 97.0 86.2 196.6 785 709 1379 1401 130.4 59.1
H391097FA02 230 1542 97.0 86.2 249.8 785 709 1379 1401 141.0 64.0
H391102FA01 230 1451 102.0 91.5 206.7 828 745 1457 1475 134.1 60.8
H391102FA02 230 1451 102.0 91.5 264.7 828 745 1457 1475 145.7 66.1
H391104FB01 345 1414 104.0 92.2 228.1 834 750 1468 1786 139.6 63.3
H391104FB02 345 141 104.0 92.2 358.8 834 750 1468 1786 168.7 75.2
H391107FB01 345 1373 107.0 95.3 240.9 861 771 1514 1530 143.2 35.0
H391107FB02 345 1373 107.0 95.3 289.3 861 771 1514 1530 152.8 69.3
H391113FB01 345 1304 113.0 101.6 285.9 912 809 1605 1618 154.2 69.9
H391113FB02 345 1304 113.0 101.6 358.5 912 809 1605 1618 168.7 76.5
H391120FB01 345 1223 120.0 108.9 264.2 972 843 1709 1719 152.2 69.0
H391120FB02 345 1223 120.0 108.9 312.6 972 843 1709 1719 161.9 73.4
H391160FE01 500 898 160.0 148.1 359.3 1282 1026 2233 2240 190.4 86.4
H391160FE02 500 898 160.0 148.1 441.5 1282 1026 2233 2240 106.8 93.8
H391170FE01 500 853 170.0 158.6 369.7 1362 1075 2365 2373 195.9 88.9
H391170FE02 500 853 170.0 158.6 452.0 1362 1075 2365 2373 212.3 96.3
H391180FE01 500 805 180.0 169.9 4149 1447 1127 2504 2514 213.3 96.8
H391180FE02 500 805 180.0 169.9 516.5 1447 1127 2504 2514 233.3 106.0
H391190FE01 500 760 190.0 180.4 425.4 1524 1176 2632 2642 218.8 99.2
H391190FE02 500 760 490.0 180.4 527.0 1524 1176 2632 2642 239.1 108.5
Notes:

1) STL ( Specified Tensile Load) - 20,000 Lbs. [89.0 kN]
2) H391 Series supplied with standard G3-0 Bendable Gain Base
3) For Flat Base F3-0, change the "9" in H391... to "1" = H311 (See base section for details)
4) For Trunnion end fitting, change the "1" in H391 ... to "2" = H392 (Trunnion limits MDCL to 2500 lbs)

5) FX - Electrical Data is without Corona Ring
6) FA - Electrical Data is with a 6" Corona Ring on the line end fitting
7) FB - Electrical Data is with a 12" Corona Ring on the line end fitting
8) FE - Electrical Data is with two 12" Corona Rings on the line and tower end fittings
9) For other ratings or custom insulator designs, contact your local MPS Sales Representative

 
 